Peerless-lighting CLM9 - T5_T5HO User Manual

Browse online or download User Manual for Lighting Peerless-lighting CLM9 - T5_T5HO. Peerless Lighting CLM9 - T5_T5HO User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SPECIFICATIONS
CATALOG NUMBER
SPECIFICATIONS
2246 5th Street, Berkeley, CA 94710 Tel: 510.845.2760 Fax: 510.845.2776 Email: [email protected] PeerlessLighting.com
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
LAMPING OPTIONS DESIGN GUIDELINES
Type: ________________________
Project: ______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Contrail” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
Indirect-Direct T5/T5HO
CLM9  Contrail Linear
Examples: CLM9 2 28T5 COA 40FT R8 277 GEB10 SCT LP835 F1/18 — CLM9 2 54T5HO COA 32FT R8 277 GEB10 1SE EL SCT LP835 F1/21
Suspended CLM9
Contrail Linear
Indirect-Direct T5/T5HO
6”
3”
CLM9 - 2
Because the shielding (diuser) is fully luminous,
color variations in the lamp may create subtle
fluctuations in the color of the shield.
If dual switching is required for energy savings,
dimming or the alternating lamp circuit switching
option (ALC) is recommended in place of the dual
circuit switching option (DCT). DCT will switch
each side of a luminaire row separately which will
aect the uniform luminous aesthetic of the lens.
ALC will switch every other 4’ section of a luminaire
row separately.
Construction
Die-formed pre-painted steel housing. Extruded
aluminum fillers. Die-cast aluminum end caps.
Highly specular aluminum end plates.
Shielding
GrateOptic curved, crenulated diuser is extruded
opal acrylic.
Reflectors
Die-formed, highly specular aluminum reflector has
a minimum 98% reflectance.
Finish
Fine-textured, white polyester powder paint is
standard on the fillers and end caps.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ individual luminaire sections for
nominal suspension spacing of 4’, 8’ and 12’. Add
3
5
8” for each end cap to determine total luminaire
length. Using internal joiners, 4’, 8’ and 12’ sections
can be joined to form longer length luminaires.
__________ __________ __________ __________ _________ __________ __________ __________ __________ __________
Luminaire
CLM9
# of
Lamps in
Cross
Section
2
Lamp Type
28T5 28W T5
54T5HO 54W T5HO
Shielding
COA Crenulated
opal
acrylic
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4 4’ section(s)
R8 8’ section(s)
R12 12’ section(s)
Voltage
120
277
347
2
Ballast Type
GEB10 <10% THD Electronic
ADEZ
1,2
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
OSDIM
1,2
Osram 0-10V dim
Reference Ballast Wizard on website
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE 1 section
2SE 2 sections
XSE X sections
Emergency Type
3
(Blank) None
EC Emergency circuit
EL
1,4
Emergency battery
pack
EN
1,4
Emergency battery
pack w/night light
circuit
______________ ________________ ______________ ______________ _________________________________
Switching
5
SCT Single circuit
ALC Alternate lamping
module circuit
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P 3000K 80+ CRI Premier
LP835P 3500K 80+ CRI Premier
LP841P 4100K 80+ CRI Premier
Reference Lamp Chart on website or
consult factory for other options.
Mounting Type /
F1/ T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/ Hard ceiling (horizontal J-box)
Overall Suspension
12 12”
15 15”
18 18”
21 21”
24 24
XX XX”
Overall suspension is
measured from ceiling to
bottom of luminaire.
Options
ACG Adjustable cable grippers
BLK Black cord, cord manager and canopy
DL Damp location label
ELH Emergency through wiring w/separate feed
ELS Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
MCS Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
OJB Oset junction box
SLP Sloped ceiling (for 10-45°, must be specified with F2, ACG and
OJB options)
XXXX Integrated sensor; choose options and obtain code on page 2
Notes:
1 Not available in 347V
2 Not available with 28T5 lamps
3 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
4 Option EL or EN (Battery Pack) is :
a. not permitted with dimming in the same row
b. must be in the same section as the lamp being operated
c. not permitted in a 4’ section
d. limited to one battery pack per section
5 SCT with or without dimming, or ALC is recommended
over DCT. DCT and ALC are not available with dimming
Page view 0
1 2

Summary of Contents

Page 1 - Contrail Linear

SPECIFICATIONSCATALOG NUMBERSPECIFICATIONS2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerl

Page 2

2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: [email protected] • PeerlessLighting.comPH

Comments to this Manuals

No comments